4800 West 92nd Avenue Westminster, CO 80031

City Government

 

Digital Submittal Standards

The City of Westminster requires that as a part of the development approval process, the applicant submits digital files of proposed improvements at the ODP approval stage and when the construction drawings are created. These files will be reviewed and translated into the city's GIS database. 

All projects shall be submitted in a digital format, either AutoCAD DXF, ESRI GIS shapefile or personal geodatabase version 9.0. AutoCAD version 2000 or greater is required. The files should be transmitted on CD or, if less than 5 Mb, through e-mail.

 

The entire project will be displayed on one sheet in the city's coordinate system (Colorado State Plane North Zone, NAD 1983 and North American Vertical Datum of 1988 - NAVD88, feet). All layers and control for the project must be aligned with the city's quarter section bearings (survey control documentation).

 

The files submitted in AutoCAD DXF format must adhere to the following naming conventions. Drawing files or other project components should not be included with this submittal.

 

LAYERS FOR PROPOSED/NEW FEATURES in a DXF file

 

 

NO LAYER DESCRIPTION Required @ FEATURE TYPE LAYER NAME TEXT
1 BUILDING FOOTPRINTS ODP LINE P-BLDG None
2 LOT/PARCEL LINES ODP & LINE P-LOTLINE None
    CONSTRUCTION DRAWINGS      
3 PROPERTY BOUNDARY ODP & CONSTRUCTION DRAWINGS LINE P-PROP-LINE Subdivision Name
  (property line or legal subdivision boundary)        
4 STREET CENTERLINES ODP & CONSTRUCTION DRAWINGS LINE P-STREET-CL Street Dir, Street Name, Street Type
NO LAYER DESCRIPTION Required @ FEATURE TYPE LAYER NAME TEXT
5 EDGE OF PAVEMENT ODP & CONSTRUCTION DRAWINGS LINE P-EOP Pavement Type
6 SURVEYED MONUMENT PTS ODP, & CONSTRUCTION DRAWINGS POINT P-MNMT T-R-S-Quarter
7 PARKING LOTS CONSTRUCTION DRAWINGS LINE P-PARKLOT  
8 ADDRESS POINTS ODP POINT P-ADDRESS Address Number, Street Dir, Street Name, Street Type, Unit
9 SANITARY SEWER LINES & SERVICE LINES CONSTRUCTION DRAWINGS LINE P-SAN-LN Material - Size
10 SANITARY SEWER MANHOLE CONSTRUCTION DRAWINGS POINT P-SAN-MH  
11 CLEANOUTS CONSTRUCTION DRAWINGS POINT P-SAN-CO  
12 OTHER SEWER POINTS CONSTRUCTION DRAWINGS POINT P-SAN-PT Type
13 STORM SEWER LINES CONSTRUCTION DRAWINGS LINE P-STM-LINE Material - Size
14 STORM SEWER INLETS CONSTRUCTION DRAWINGS POINT P-STM-INLET Type
15 STORM MANHOLE CONSTRUCTION DRAWINGS POINT P-STM-MH  
16 STORM OUTLET CONSTRUCTION DRAWINGS POINT P-STM-OUTLET Outlet Type
17 OTHER STORM POINTS CONSTRUCTION DRAWINGS POINT P-STM-PT Storm Point Type
18 WATER LINES CONSTRUCTION DRAWINGS LINE P-W-LINE Material – Size
19 WATER VALVE CONSTRUCTION DRAWINGS POINT P-WV Water Valve Type
NO LAYER DESCRIPTION Required @ FEATURE TYPE LAYER NAME TEXT
20 FIRE HYDRANT CONSTRUCTION DRAWINGS POINT P-W-FH  
21 FIRE HYDRANT VALVE CONSTRUCTION DRAWINGS POINT P-W-FH-VALVE  
22 RAW WATER LINES CONSTRUCTION DRAWINGS LINE P-RAW-LN Material -Size
23 RAW WATER POINTS CONSTRUCTION DRAWINGS POINT P-RAW-PT Type
24 RECLAIMED WATER LINES CONSTRUCTION DRAWINGS LINE P-RECLAIM-LN Material - Size
25 RECLAIMED WATER POINTS CONSTRUCTION DRAWINGS POINT P-RECLAIM-PT Type
 26  IRRIGATED AREAS  CONSTRUCTION DRAWINGS  POLYGON IRRAREA  

 

 

For additional information, please contact Dave Murray, GIS coordinator, 303-658-2140, dmurray@cityofwestminster.us.

 

  |